Before using the oil-water separator, the turbine operation and management personnel should understand the start-up, operation and maintenance requirements of the separator according to the use and maintenance instructions of the product.
1: Start-up inspection and preparation
1: Before using the oil-water separator equipment to discharge, the consent of the bridge should be obtained
2: Check the line installation of the oil-water separator and whether the steering of the matching pump is normal
3: Supply water to the oil-water separator, open the top air valve to let the air escape
4: Check that there is no leakage on the water inlet and outlet systems of the oil-water separator
Two: Precautions during operation
1: Adjust the opening of the valve of the drain water pipeline to keep the pressure in the separator, so as to facilitate the removal of dirty oil in the separator
2: Observe whether the pressure gauge, temperature gauge and other indicating instruments are normal
3: Observe the working condition of the treated drainage water quality and oil concentration alarm
4: After the discharge is completed, continue to inject clean water for 15 minutes to clean the separator
5: After stopping the pump, close the inlet and outlet valves to avoid the loss of clean water in the cylinder and reduce the oxidation and corrosion of the inner wall
6: Every time the oil-water separator is used to discharge, it should be recorded in the oil record book
Three: maintenance
1: Clean the filter regularly, open the discharge valve at the bottom of the separator, and remove the sediment and impurities deposited in the lower part
2: Clean the internal separation components of the separator in time, and do not use cleaning agents to clean the inner wall and components of the separator
3: When a failure occurs, the cause should be identified and the failed coalescing element should be replaced in time
Four: Internal anticorrosion